The Powerbank Series System is a True on-line UPS System with state-of-the-art IGBT based system. With a Rugged Robust design to provide fit-and-forget reliability and with a capacity of 6 kVA, this one is a workhorse!
The Powerbank features total isolation of the load from the mains - isolating input and output sections which is ideal for VSAT applications. Configurable in hot standby configuration - Ideal product for critical applications(banks etc).
Wide input voltage (165V-265V) - Ideal for Indian Power conditions. This is a high availability Emerson Liebert UPS System.
Some other salient Features of the Powerbank:
True On Line IGBT based Systems.
Cold Start on full load facility. Even under black out conditions the Powerbank can be switched on.
1+1 Hot Standby Configuration.
Battery Charging Current Selector.
Generator Capability.
Static Bypass with Zero Transfer.
Multilink Auto Shutdown Software.
Input overvoltage cutoff devices - Provides complete protection to system during high input voltage conditions.
Backup upto 4 hours possible
Excellent overload features 150 FL for 5 seconds
Output short circuit protection - Protects system from output faults at the load end.
Battery charging current selection - optimises battery charging which improves life of batteries.
The Powerbank features total isolation of the load from the mains - isolating input and output sections which is ideal for VSAT applications. Configurable in hot standby configuration - Ideal product for critical applications(banks etc).
Wide input voltage (165V-265V) - Ideal for Indian Power conditions. This is a high availability Emerson Liebert UPS System.
Some other salient Features of the Powerbank:
True On Line IGBT based Systems.
Cold Start on full load facility. Even under black out conditions the Powerbank can be switched on.
1+1 Hot Standby Configuration.
Battery Charging Current Selector.
Generator Capability.
Static Bypass with Zero Transfer.
Multilink Auto Shutdown Software.
Input overvoltage cutoff devices - Provides complete protection to system during high input voltage conditions.
Backup upto 4 hours possible
Excellent overload features 150 FL for 5 seconds
Output short circuit protection - Protects system from output faults at the load end.
Battery charging current selection - optimises battery charging which improves life of batteries.