Sr. No. | No. Of Strands SWG | ATC Cond Size MM | ATC Cond. Size Inches | Current carrying
capacity (Amps) |
Cross Sec. Area Sq MM | Max Conductor Resistance at 20 dc | Nominal Insulation Thickness MM | Maximum overall dia MM (+-2) |
1
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 |
7/42
7/39 7/39 7/38 7/38 7/37 7/36 10/38 14/40 14/39 14/38 14/37 14/36 23/38 23/36 40/38 40/36 7/0.2 16/0.2 24/0.2 32/0.2 48/0.2 80/0.2 |
0.102
0.132 0.132 0.152 0.152 0.173 0.193 0.152 0.122 0.132 0.152 0.173 0.193 0.152 0.193 0.152 0.193 0.203 0.203 0.203 0.203 0.203 0.203 |
0.0040
0.0052 0.0052 0.0060 0.0060 0.0068 0.0076 0.0060 0.0048 0.0052 0.0060 0.0068 0.0076 0.0068 0.0076 0.0060 0.0076 0.0800 0.0080 0.0080 0.0080 0.0080 0.0080 |
0.3
0.5 0.5 1 1 1.3 1.6 1.4 1.3 1.5 2 2.5 3 3.3 5.3 7 12 1.75 4 7 11 14 19 |
0.0572
0.1 0.1 0.13 0.13 0.16 0.2 0.18 0.16 0.19 0.25 0.33 0.41 0.42 0.67 0.73 1.17 0.22 0.5 0.75 1 1.5 2.5 |
301.57
202.5 202.5 152.7 152.7 117.9 94.7 106.9 118.5 101.3 76.4 58.9 47.4 46.5 28.8 26.7 16.6 88.2 38.6 25.7 19.3 12.9 |
0.25
0.35 0.45 0.3 0.45 0.45 0.45 0.45 0.55 0.55 0.55 0.55 0.55 0.65 0.65 0.85 0.85 0.4 0.55 0.55 0.7 0.7 |
0.7
1.1 1.3 1 1.35 1.4 1.4 1.4 1.6 1.7 1.75 1.8 1.8 2.2 2.4 2.75 3 1.4 2.1 2.3 2.7 3 |
Products of other enterprises
Description
Multistrand Tin copper conductors.for better connectivity & insulated with special grade pvc compound, temperature range -20°c to +80°c. Mainly used for internal wiring of electronic circuits, control panels & various type of equipments, appliances.
Contact the seller
Flexible Wires
We recommend to see